SP POWERWORLD EG3002
Universal Electronic Engine Governor Controller
The EG3002 is an updated version of the EG3000. It comes with smoke limit, idle speed control and a New Slow response mode. It's suitable for diesel, gas and natural gas engines with Built-in & Non-Built-in PTs Pumps. Used worldwide as a Compatible Replacement for the following models:
Cummins: 3062322 - 3419988 - 3098693 - 3044196 - 4913988-BI.
Barber Colman: DYN1 10794-000-0-24 - DYN1 10794-000-0-12 - DYN1-10654-000-0-24 - DYN1-1065X Series - DYN1-1069X Series - DYN1-10754-000-0-12 - DYN1-10754-001-0-24 - DYN1-10704-000-0-12 - DYN1-10704-000-0-24 - DYN1-10754-004-0-24. GAC: ESD2210-12 - ESD5111 - ESD5221 - ESD5500 - ESD5500E - ESD5500E K77255 - ESD5550 - ESC63C.
Woodward: 8290-038 - 8290-147 - 8290-185 - 8290-190 - 8290-044 - 8290-184 - 8270-1033 (12V) - EPG P/N 8290-189 - DPG2101-000-012 - DPG-2104 - DPG-2201-002*
Ex stock - shipped Worldwide. For GBP, EURO or USD pricing please contact us:
Sales: james.daff@sp-powerworld.com
Office: info@sp-powerworld.com
Tel: +44 (0)115 923 2568 (United Kingdom)
Tel: (24-hour) +44 (0)7484709956 (United Kingdom)
*All manufacturer names, numbers, symbols and descriptions are used for reference purpose only and do not imply that any part is the product of these manufacturers.
Features
- It can be used in a wide range of input frequencies
 - 15 Amp maximum current output
 - Suitable for all diesel, natural gas, and petrol (gasoline) engines
 - Fast response time limits variations in speed (high stability)
 - Injected epoxy housing provides high resistance to moisture, vibration, and oxidation
 - Can connect with external potentiometer for remote speed control
 - Adjustable Engine Idle speed setting
 - Accepts analog signal inputs from other controllers to control speed
 
Specifications
- Operating Voltage
 - 10 to 32 Vdc
 
- Outputs Current
 - Continuous 7A, Max. 15A for 10 seconds
 
- MPU Frequency input
 - 10 to 10,000 Hz
 
- MPU Voltage input
 - 1 to 120 Vac
 
- Idle Adjustment Range
 - 30 to 90% of Normal Speed
 
- Speed Temperature Shift
 - -40 to +80 °C, less than 3%
 
- Ramp Time
 - 3 to 20 seconds (adjustable)
 
- Remote Speed Adjustment Range
 - +/-7% @ 5K ohms 1 Watt potentiometer
 
- Isochronous Load Sharing (ILS)
 - +/-5 Vdc or 0 to 10 Vdc
 
- Speed Droop (DROOP)
 - 0 to 4% (adjustable)
 
- Stability
 - Speed variation less than +/-0.25% at constant load
 
- Static Power Consumption
 - Less than 1 Watt @ 12 Vdc
Less than 2 Watt @ 24 Vdc 
DIP Switch Settings
- SW1 ON
 - 600 to 1200 Hz
 
- SW2 ON
 - 1200 to 2500 Hz
 
- SW3 ON
 - 2500 to 5000 Hz
 
- SW4 ON
 - 5000 to 9500 Hz
 
- SW5 ON
 - Cummins PT PUMP
 
- SW6 ON
 - Extreme slow response engine
 
Control Characteristic Settings
- DROOP
 - Speed Droop setting
 
- GAIN
 - Gain setting
 
- INT.
 - Integral setting
 
- DIF
 - Differential setting
 
- RAMP
 - Ramp Time
 
- IDLE SPEED
 - Idle speed setting
 
- RUN SPEED
 - Operating speed setting
 
Environment
- Operating Temperature
 - -40 to +80 °C
 
- Storage Temperature
 - -40 to +85 °C
 
- Relative Humidity
 - Max. 95%
 
- Vibration
 - 5.5 Gs @ 60 Hz
 
Physical Specifications
- Dimensions
 - 147.0 (L) x 114.0 (W) x 50.0 (H) mm
5.79 (L) x 4.49 (W) x 1.97 (H) inch 
- Weight
 - 690 g +/-2%
1.52 lb +/-2%